共找到 150 条与 Flammable component 相关的标准,共 10 页
This focused set of TIA Standards specifies the minimum performance requirements for the cable and components of structured data/phone cabling systems. Standards for copper (Category) cables@ optical fiber cables@ coaxial cables@ and connectors@ are included. These Standards specify the components that are used to construct generic telecommunications cabling for a multi product@ multi vendor environment and are the foundation for telecommunications cabling infrastructure throughout the world. This set includes: TIA-568-C.2: Balanced Twisted-Pair Telecommunications Cabling and Components Standards TIA-568-C.3 Optical Fiber Cabling Components Standard TIA-568-C.4: Broadband Coaxial Cabling and Components Standard
TIA COMPONENT OF 3 TIA TR-42 STANDARDS. *** YOU SAVE 35% WHEN PURCHASING AS A SET ***
This Directory contains the names of companies authorized to use the UL Recognized Component Mark on or in connection with components that have been investigated by UL and found to be in compliance with UL’s requirements. These companies, as well as the manufacturers and submitters of the components, have entered into an Agreement with UL to use the UL Recognized Component Marking only on or in connection with components manufactured in compliance with UL’s requirements. It should be noted that the Recognized Components of different makes or model designations are not necessarily equivalent in quality or performance. For information concerning Plastics Recognized Components, refer to UL’s Plastics Recognized Component Directory. UL investigations of products or equipment for the UL Listing/Classification Mark generally include an evaluation of the suitability of components (i.e. relays, switches, plastics, etc.) for use in the specific end-product. Recognized Components are intended for factory installation in end-products or equipment where the limitations of use are known to the end-product manufacturer and where their use is within such limitations as evaluated by UL. The conditions of acceptability of the Recognized Component need to be compatible with the specific end-product application. Since these components may be incomplete in construction and/or restricted in performance capabilities, they are not certified by UL for use as field-installed components. UL’s Component Recognition Service evaluates components by establishing performance requirements and/or construction requirements for use in specific end-product applications. The appearance of catalog or model numbers or other specific component designations in this Directory signifies that: (1) representative samples of these components have been submitted to UL and found to comply with the applicable requirements, and that (2) the manufacturer has been authorized to use the Recognized Component Marking on production that continues to comply with UL’s requirements and is subject to UL’s Follow-Up Service. Since manufacturers are not obligated to apply the UL Mark on all of their production, components that do not bear the UL Recognized Component Marking are not required by UL to comply with UL’s requirements. The manufacturer’s products are not subject to UL’s Follow-Up Service unless they bear the UL Recognized Component Marking. Only those components bearing the appropriate UL Recognized Component Marking should be considered as being covered by UL’s Recognition and Follow-Up Service. The Recognized Component Directory is intended to assist manufacturers who may wish to use a Recognized Component in their end products. For some components, part or all of the use conditions and ratings are indicated in the Component Category Guide Information and the individual Recognitions. Information and limitations on the component can be obtained by contacting the component manufacturer at the address specified for the individual Recognition in the Directory. This Directory contains Recognitions in effect as of February 15, 2008. Records of Recognitions issued or withdrawn after this date will be found in UL’s Listing Information database. In addition, Recognitions issued after the effective date will be found in UL’s Online Certifications Directory at www.ul.com/ database and will appear in the next annual printed Directory. Users of this Directory are urged to read carefully the following sections for an understanding of the extent of UL’s services.
RECOGNIZED COMPONENT DIRECTORY 2008
RECOGNIZED COMPONENT DIRECTORY
Recognized Component Directory 3 Volume Set; See Individual Volumes for Images
Recognized Component Directory 3 Volume Set; See Individual Volumes for Images
Recognized Component Directory
Recognized Component Directory
Flammable and Combustible Liquids and Gases Equipment Directory
Flammable and Combustible Liquids and Gases Equipment Directory
This Directory contains the names of companies authorized to use the UL Mark on or in connection with products that have been investigated by UL and found to be in compliance with UL’s requirements. These companies, as well as the manufacturers and submitters of the products, have entered into an Agreement with UL to use the UL Mark only on or in connection with products manufactured in compliance with UL’s requirements. It should be noted that UL certified products of different makes or model designations are not necessarily equivalent in quality or performance. The appearance of catalog or model numbers or other specific product designations in this Directory signifies that: (1) representative samples of these products have been submitted to UL and found to comply with the applicable requirements, and that (2) the manufacturer has been authorized to use the appropriate UL Mark on production that continues to comply withUL’s requirements and is subject to UL’s Follow-Up Service. Since manufacturers are not obligated to apply the UL Mark on all of their production, products that do not bear the UL Mark are not required by UL to comply with UL’s requirements. Accordingly, the appearance of a company’s name or a specific product designation in this Directory does not in itself ensure that products so specified or identified are subject to UL’s Follow-Up Service. The manufacturer’s products are not subject to UL’s Follow-Up Service unless they bear the UL Mark. Only those products bearing the appropriate UL Mark and the company’s name, trade name, trademark or other authorized identification should be considered as being covered by UL’s Listing or Classification and Follow-Up Service. The UL Mark provides evidence of listing or labeling, which may be required by installation codes or standards.
FLAMMABLE AND COMBUSTIBLE LIQUIDS AND GASES EQUIPMENT DIRECTORY 2008
Flammable and Combustible Liquids and Gases Equipment Directory
Flammable and Combustible Liquids and Gases Equipment Directory
This Directory contains the names of companies authorized to use the UL Mark on or in connection with products that have been investigated by UL and found to be in compliance with UL’s requirements. These companies, as well as the manufacturers and submitters of the products, have entered into an Agreement with UL to use the UL Mark only on or in connection with products manufactured in compliance with UL’s requirements. It should be noted that UL certified products of different makes or model designations are not necessarily equivalent in quality or performance.
Flammable and Combustible Liquids and Gases Equipment
Flammable and combustible liquids and gases equipment birectory
RECOGNIZED COMPONENT AND PLASTICS RECOGNIZED COMPONENT
Recognized Component Directory Volume 1 - AAYZ2 to PFZK2
Recognized Component Directory Volume 1 - AAYZ2 to PFZK2
Recognized Component Directory Volume 2 - PGDQ2 to QQPX2
Recognized Component Directory Volume 2 - PGDQ2 to QQPX2
Recognized Component Directory Volume 3 - QQQX2 to ZQQF2
Recognized Component Directory Volume 3 - QQQX2 to ZQQF2
本标准规定了可燃液体和可燃气体(例如用于驱动、辅助操作、加热或厨房美利体育官网首页网址)装置的要求,以实现 EN 45545-1 中定义的防护目标。本部分不适用于技术液体本身,例如液压油、变压器油,除非规定了关于溢出、泄漏和喷雾产生的要求。本欧洲标准中描述的测量和措施旨在通过防止因可燃液体或气体泄漏而产生的火灾发生和蔓延,保护铁路车辆上的乘客和人员。其他可燃气体(液化石油气除外)的措施不属于本欧洲标准的适用范围。确保在火灾中维持铁路车辆的措施不属于本欧洲标准的适用范围。
Railway applications - Fire protection on railway vehicles - Part 7: Fire safety requirements for flammable liquid and flammable gas installations; German version EN 45545-7:2013
Copyright ?2007-2026 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号